All boiler fault codes

126 codes from 7 boiler brands

All 126 codes on this site, brand by brand. Each one links to what the code means, what you can safely try and when you need a Gas Safe engineer.

Jump to: Worcester Bosch · Vaillant · Ideal · Baxi · Glow-worm · Viessmann · Alpha

Worcester Bosch

CodeWhat it meansWhat to do
202Anti-cycle mode (not a fault)Not a fault
1017System pressure too lowSafe checks first
2910Fault in the flue systemStop: safety risk
A1 281Pump stuck or running drySafe checks first
A7 808Hot water sensor faultEngineer needed
C6 216Fan speed too low (or too high)Engineer needed
C7 214Fan not runningEngineer needed
CC 800Outdoor sensor faultEngineer needed
D4 341Water temperature rising too fastEngineer needed
E2 222Flow temperature sensor faultEngineer needed
E9 224Overheat or flue thermostat has trippedEngineer needed
E9 276Flow temperature went above 95 °CEngineer needed
EA 227No flame detected after ignitionSafe checks first
EA 229Flame lost while the boiler was runningSafe checks first
F0 280Control box faultEngineer needed
F7 228Flame signal before the burner startedEngineer needed
FA 306Flame signal after the gas valve closedEngineer needed
Fd 231Power cut while the boiler was locked outSafe checks first
SEService due reminderNot a fault

Vaillant

CodeWhat it meansWhat to do
F.0Flow temperature sensor faultEngineer needed
F.1Return temperature sensor faultEngineer needed
F.20Overheat cut-out has trippedEngineer needed
F.22Low water pressureSafe checks first
F.23Flow and return temperature difference too bigEngineer needed
F.24Temperature rising too quicklyEngineer needed
F.25Flue gas temperature too highEngineer needed
F.27Flame detected while the burner is offEngineer needed
F.28Boiler failed to lightSafe checks first
F.29Flame went out and the boiler couldn't relightSafe checks first
F.32Fan faultEngineer needed
F.35Air or flue pipe blockedStop: safety risk
F.53Combustion control faultSafe checks first
F.54Gas supply faultSafe checks first
F.57Not burning correctly in comfort modeSafe checks first
F.62Delay in the flame going outEngineer needed
F.70Wrong device numberEngineer needed
F.72Flow and return sensor readings don't agreeEngineer needed
F.75Pressure sensor or pump faultSafe checks first
F.83No temperature rise when the burner startsEngineer needed
F.84Implausible flow and return temperaturesEngineer needed
F.88Gas valve connection interruptedEngineer needed

Ideal

CodeWhat it meansWhat to do
0Standby (not a fault)Not a fault
CCentral heating on (not a fault)Not a fault
dHot water on (not a fault)Not a fault
F1Low water pressureSafe checks first
F2Flame lossSafe checks first
F3Fan faultEngineer needed
F4Flow thermistor faultEngineer needed
F7Low mains voltageSafe checks first
FAFlow and return reversedSafe checks first
L2Ignition lockoutSafe checks first
L5Problem with the returnEngineer needed
Too many restartsReset five times in 15 minutesEngineer needed

Baxi

CodeWhat it meansWhat to do
A.02.06Low system pressureSafe checks first
E20Central heating sensor faultEngineer needed
E28Flue sensor, flue or condensate blockageSafe checks first
E50Hot water sensor faultEngineer needed
E110Boiler overheatedEngineer needed
E118Water pressure too lowSafe checks first
E119Water pressure too lowSafe checks first
E125Circulation faultEngineer needed
E128Flame failure during operationSafe checks first
E130Flue overheatEngineer needed
E133Gas supply or ignition failureSafe checks first
E160Fan faultEngineer needed
E.01.04Flame lost five times in 24 hoursSafe checks first
E.01.17No water circulationEngineer needed
E.01.20Maximum flue temperature reachedEngineer needed
E.04.08Maximum safe temperature reachedEngineer needed
E.04.10Burner failed to igniteSafe checks first
E.04.12Ignition failure: flame monitoringEngineer needed
E.04.13Fan blocked or over-speedEngineer needed
H.01.08Heating temperature rising too fastSafe checks first
H.02.07Pressure too low (permanent)Safe checks first
H.03.05Power supply voltage too lowSafe checks first

Glow-worm

CodeWhat it meansWhat to do
ErrUser interface problemEngineer needed
F.0Flow temperature sensor faultEngineer needed
F.1Return temperature sensor faultEngineer needed
F.20Overheat cut-out has trippedEngineer needed
F.22Low water pressureSafe checks first
F.23Flow and return temperature difference too greatEngineer needed
F.24Temperature rising too quicklyEngineer needed
F.25Flue gas temperature too highEngineer needed
F.27Flame detected while the burner is offEngineer needed
F.28Boiler failed to lightSafe checks first
F.29Flame went out and didn't relightSafe checks first
F.32Fan faultEngineer needed
F.61Gas valve control or main board faultEngineer needed
F.70Invalid product codeEngineer needed
F.72Sensor readings don't agreeEngineer needed
F.75Pressure sensor or pump faultSafe checks first
F.83No temperature rise when the burner startsEngineer needed
F.88Gas valve connection interruptedEngineer needed
F.89Pump faultEngineer needed

Viessmann

CodeWhat it meansWhat to do
59Power supply undervoltageSafe checks first
62High limit safety cut-outEngineer needed
63Flue gas temperature limiter trippedEngineer needed
67Flame signal out of rangeSafe checks first
68Flame detected before the burner startedEngineer needed
71Fan speed too lowEngineer needed
73Internal communication errorEngineer needed
74System pressure too lowSafe checks first
89Pump blockedEngineer needed
184Flow temperature sensor faultEngineer needed
345Temperature limiter tripped (restarts by itself)Engineer needed
346Flame signal calibration errorSafe checks first
352Carbon monoxide limit exceededStop: safety risk

Alpha

CodeWhat it meansWhat to do
E01Ignition failureSafe checks first
E02Overheat lockoutEngineer needed
E03High flue temperatureEngineer needed
E04Gas valve electrical faultEngineer needed
E05Heating flow sensor faultEngineer needed
E06Hot water sensor faultEngineer needed
E08Maximum number of resets reachedEngineer needed
E10Primary system pressure lowSafe checks first
E16Fan faultEngineer needed
E20Flame sensing faultEngineer needed
E27Primary circuit overheatEngineer needed
E37Low supply voltageSafe checks first
E38Flame lost (can be high winds)Safe checks first
E43Repeated flame lossEngineer needed
E45Flow and return difference too highSafe checks first
E47Output reduced: flue running hotEngineer needed
E60Pump faultEngineer needed
E61Air in the pumpSafe checks first
SrService reminderNot a fault