All 126 codes on this site, brand by brand. Each one links to what the code means, what you can safely try and when you need a Gas Safe engineer.
Jump to: Worcester Bosch · Vaillant · Ideal · Baxi · Glow-worm · Viessmann · Alpha
| Code | What it means | What to do |
|---|
| 202 | Anti-cycle mode (not a fault) | Not a fault |
| 1017 | System pressure too low | Safe checks first |
| 2910 | Fault in the flue system | Stop: safety risk |
| A1 281 | Pump stuck or running dry | Safe checks first |
| A7 808 | Hot water sensor fault | Engineer needed |
| C6 216 | Fan speed too low (or too high) | Engineer needed |
| C7 214 | Fan not running | Engineer needed |
| CC 800 | Outdoor sensor fault | Engineer needed |
| D4 341 | Water temperature rising too fast | Engineer needed |
| E2 222 | Flow temperature sensor fault | Engineer needed |
| E9 224 | Overheat or flue thermostat has tripped | Engineer needed |
| E9 276 | Flow temperature went above 95 °C | Engineer needed |
| EA 227 | No flame detected after ignition | Safe checks first |
| EA 229 | Flame lost while the boiler was running | Safe checks first |
| F0 280 | Control box fault | Engineer needed |
| F7 228 | Flame signal before the burner started | Engineer needed |
| FA 306 | Flame signal after the gas valve closed | Engineer needed |
| Fd 231 | Power cut while the boiler was locked out | Safe checks first |
| SE | Service due reminder | Not a fault |
| Code | What it means | What to do |
|---|
| F.0 | Flow temperature sensor fault | Engineer needed |
| F.1 | Return temperature sensor fault | Engineer needed |
| F.20 | Overheat cut-out has tripped | Engineer needed |
| F.22 | Low water pressure | Safe checks first |
| F.23 | Flow and return temperature difference too big | Engineer needed |
| F.24 | Temperature rising too quickly | Engineer needed |
| F.25 | Flue gas temperature too high | Engineer needed |
| F.27 | Flame detected while the burner is off | Engineer needed |
| F.28 | Boiler failed to light | Safe checks first |
| F.29 | Flame went out and the boiler couldn't relight | Safe checks first |
| F.32 | Fan fault | Engineer needed |
| F.35 | Air or flue pipe blocked | Stop: safety risk |
| F.53 | Combustion control fault | Safe checks first |
| F.54 | Gas supply fault | Safe checks first |
| F.57 | Not burning correctly in comfort mode | Safe checks first |
| F.62 | Delay in the flame going out | Engineer needed |
| F.70 | Wrong device number | Engineer needed |
| F.72 | Flow and return sensor readings don't agree | Engineer needed |
| F.75 | Pressure sensor or pump fault | Safe checks first |
| F.83 | No temperature rise when the burner starts | Engineer needed |
| F.84 | Implausible flow and return temperatures | Engineer needed |
| F.88 | Gas valve connection interrupted | Engineer needed |
| Code | What it means | What to do |
|---|
| 0 | Standby (not a fault) | Not a fault |
| C | Central heating on (not a fault) | Not a fault |
| d | Hot water on (not a fault) | Not a fault |
| F1 | Low water pressure | Safe checks first |
| F2 | Flame loss | Safe checks first |
| F3 | Fan fault | Engineer needed |
| F4 | Flow thermistor fault | Engineer needed |
| F7 | Low mains voltage | Safe checks first |
| FA | Flow and return reversed | Safe checks first |
| L2 | Ignition lockout | Safe checks first |
| L5 | Problem with the return | Engineer needed |
| Too many restarts | Reset five times in 15 minutes | Engineer needed |
| Code | What it means | What to do |
|---|
| A.02.06 | Low system pressure | Safe checks first |
| E20 | Central heating sensor fault | Engineer needed |
| E28 | Flue sensor, flue or condensate blockage | Safe checks first |
| E50 | Hot water sensor fault | Engineer needed |
| E110 | Boiler overheated | Engineer needed |
| E118 | Water pressure too low | Safe checks first |
| E119 | Water pressure too low | Safe checks first |
| E125 | Circulation fault | Engineer needed |
| E128 | Flame failure during operation | Safe checks first |
| E130 | Flue overheat | Engineer needed |
| E133 | Gas supply or ignition failure | Safe checks first |
| E160 | Fan fault | Engineer needed |
| E.01.04 | Flame lost five times in 24 hours | Safe checks first |
| E.01.17 | No water circulation | Engineer needed |
| E.01.20 | Maximum flue temperature reached | Engineer needed |
| E.04.08 | Maximum safe temperature reached | Engineer needed |
| E.04.10 | Burner failed to ignite | Safe checks first |
| E.04.12 | Ignition failure: flame monitoring | Engineer needed |
| E.04.13 | Fan blocked or over-speed | Engineer needed |
| H.01.08 | Heating temperature rising too fast | Safe checks first |
| H.02.07 | Pressure too low (permanent) | Safe checks first |
| H.03.05 | Power supply voltage too low | Safe checks first |
| Code | What it means | What to do |
|---|
| Err | User interface problem | Engineer needed |
| F.0 | Flow temperature sensor fault | Engineer needed |
| F.1 | Return temperature sensor fault | Engineer needed |
| F.20 | Overheat cut-out has tripped | Engineer needed |
| F.22 | Low water pressure | Safe checks first |
| F.23 | Flow and return temperature difference too great | Engineer needed |
| F.24 | Temperature rising too quickly | Engineer needed |
| F.25 | Flue gas temperature too high | Engineer needed |
| F.27 | Flame detected while the burner is off | Engineer needed |
| F.28 | Boiler failed to light | Safe checks first |
| F.29 | Flame went out and didn't relight | Safe checks first |
| F.32 | Fan fault | Engineer needed |
| F.61 | Gas valve control or main board fault | Engineer needed |
| F.70 | Invalid product code | Engineer needed |
| F.72 | Sensor readings don't agree | Engineer needed |
| F.75 | Pressure sensor or pump fault | Safe checks first |
| F.83 | No temperature rise when the burner starts | Engineer needed |
| F.88 | Gas valve connection interrupted | Engineer needed |
| F.89 | Pump fault | Engineer needed |
| Code | What it means | What to do |
|---|
| 59 | Power supply undervoltage | Safe checks first |
| 62 | High limit safety cut-out | Engineer needed |
| 63 | Flue gas temperature limiter tripped | Engineer needed |
| 67 | Flame signal out of range | Safe checks first |
| 68 | Flame detected before the burner started | Engineer needed |
| 71 | Fan speed too low | Engineer needed |
| 73 | Internal communication error | Engineer needed |
| 74 | System pressure too low | Safe checks first |
| 89 | Pump blocked | Engineer needed |
| 184 | Flow temperature sensor fault | Engineer needed |
| 345 | Temperature limiter tripped (restarts by itself) | Engineer needed |
| 346 | Flame signal calibration error | Safe checks first |
| 352 | Carbon monoxide limit exceeded | Stop: safety risk |
| Code | What it means | What to do |
|---|
| E01 | Ignition failure | Safe checks first |
| E02 | Overheat lockout | Engineer needed |
| E03 | High flue temperature | Engineer needed |
| E04 | Gas valve electrical fault | Engineer needed |
| E05 | Heating flow sensor fault | Engineer needed |
| E06 | Hot water sensor fault | Engineer needed |
| E08 | Maximum number of resets reached | Engineer needed |
| E10 | Primary system pressure low | Safe checks first |
| E16 | Fan fault | Engineer needed |
| E20 | Flame sensing fault | Engineer needed |
| E27 | Primary circuit overheat | Engineer needed |
| E37 | Low supply voltage | Safe checks first |
| E38 | Flame lost (can be high winds) | Safe checks first |
| E43 | Repeated flame loss | Engineer needed |
| E45 | Flow and return difference too high | Safe checks first |
| E47 | Output reduced: flue running hot | Engineer needed |
| E60 | Pump fault | Engineer needed |
| E61 | Air in the pump | Safe checks first |
| Sr | Service reminder | Not a fault |