Baxi boiler fault codes
Baxi fault codes explained: what each error code on a Baxi boiler means, what you can safely check yourself and when you need a Gas Safe registered engineer. Every meaning comes from Baxi's own error code list and manuals.
Baxi has used two styles of code. Older boilers, such as the Duo-tec, Platinum and Assure, show an E with a number (E119, E133). Newer boilers, such as the 400, 600 and 800 Combi 2, show a letter and two pairs of numbers (A.02.06, E.04.10). We cover both.
How Baxi boilers show a fault
On older Baxi boilers the code is an E followed by two or three digits. Some models show a long code in two halves: E133 appears as E1 then 33.
Newer Baxi boilers show codes such as H.02.07 or E.04.10. Baxi's user guide for the 800 Combi 2 says a small spanner symbol on the display means you should contact a Gas Safe registered engineer or Baxi Customer Support.
Resetting a Baxi boiler
How you reset depends on the model. Baxi says:
- Boilers with a reset button: press it until the red light goes out.
- Boilers with a thermostat knob: turn the knob fully anticlockwise and hold it until the red light goes out.
- Boilers with an on, off and selector switch: turn the selector to R and hold it for at least 5 seconds.
Baxi says that if the boiler locks out often, there's a fault and you should contact your installer or a service engineer. See our guide to resetting a boiler.
Every Baxi code on this site
22 codes, grouped by the kind of fault. Choose a code for what it means, what you can safely try and when you need an engineer.
Ignition and flame faults
| Code | What it means | What to do |
|---|---|---|
| E128 | Flame failure during operation | Safe checks first |
| E133 | Gas supply or ignition failure | Safe checks first |
| E.01.04 | Flame lost five times in 24 hours | Safe checks first |
| E.04.10 | Burner failed to ignite | Safe checks first |
| E.04.12 | Ignition failure: flame monitoring | Engineer needed |
Water pressure and circulation faults
| Code | What it means | What to do |
|---|---|---|
| A.02.06 | Low system pressure | Safe checks first |
| E118 | Water pressure too low | Safe checks first |
| E119 | Water pressure too low | Safe checks first |
| E125 | Circulation fault | Engineer needed |
| E.01.17 | No water circulation | Engineer needed |
| H.02.07 | Pressure too low (permanent) | Safe checks first |
Overheating faults
| Code | What it means | What to do |
|---|---|---|
| E110 | Boiler overheated | Engineer needed |
| E130 | Flue overheat | Engineer needed |
| E.01.20 | Maximum flue temperature reached | Engineer needed |
| E.04.08 | Maximum safe temperature reached | Engineer needed |
| H.01.08 | Heating temperature rising too fast | Safe checks first |
Fan and flue faults
| Code | What it means | What to do |
|---|---|---|
| E28 | Flue sensor, flue or condensate blockage | Safe checks first |
| E160 | Fan fault | Engineer needed |
| E.04.13 | Fan blocked or over-speed | Engineer needed |
Sensor faults
| Code | What it means | What to do |
|---|---|---|
| E20 | Central heating sensor fault | Engineer needed |
| E50 | Hot water sensor fault | Engineer needed |
Electrical and control faults
| Code | What it means | What to do |
|---|---|---|
| H.03.05 | Power supply voltage too low | Safe checks first |
Contact Baxi
- Baxi Customer Support: 0330 678 0917
Numbers as published in Baxi's own documents, checked 25 November 2026.
Where these codes come from
Every code meaning on our Baxi pages comes from these Baxi documents:
- Boiler error codes (Baxi, baxi.co.uk)
- Baxi 800 Combi 2 user guide (Baxi, baxi.co.uk)
- Platinum+ 40 Combi installation and service manual (Baxi, baxi.co.uk)
- Baxi Assure Combi installation and service manual (Baxi, baxi.co.uk)
- What do Baxi error codes E28, E53, E133, E119 or E128 mean? (Baxi, baxi.co.uk)
- How to reset a Baxi boiler (Baxi, baxi.co.uk)
- How to thaw a frozen boiler condensate pipe (Baxi, baxi.co.uk)
Codes last checked against the manufacturers' manuals on 25 November 2026.