Alpha E38 fault code explained

Safe checks first

E38 on an Alpha boiler means the flame lit but the signal was lost, so the boiler purges and tries again. Alpha notes that strong winds on the flue can cause it. It may only appear in the fault history. If the boiler keeps cutting out, call an engineer.

Safe checks firstSimple checks outside the boiler casing often clear this code. If it keeps coming back, call a Gas Safe registered engineer.

What E38 means

Alpha's description: Flame detected but signal lost. Ignition retries after fan purge.

Alpha describes E38 as loss of flame rectification: a flame was detected, then the signal was lost, and the boiler retries ignition after purging with the fan.

Alpha's manual notes that this fault can occur if the flue is exposed to high winds, and that it's shown as E38 in the fault code history in the INFO menu.

Common causes

  • Strong wind blowing on the flue outlet.
  • Flue gases being drawn back in.
  • A flame sensing electrode or lead fault.
  • Low gas pressure.

What you can safely try

Only if you feel confident, and only outside the casing:

  1. If it's very windy, the boiler should recover once the wind drops.
  2. Check the gas supply. See checking your gas supply.
  3. Reset once if the boiler has locked out.

What not to try

  • Don't open the casing or keep resetting the boiler: work inside a gas boiler is a job for a Gas Safe registered engineer.

When you need a Gas Safe engineer

If E38 happens often, or in calm weather, call a Gas Safe registered engineer or Alpha's technical helpline on 0344 871 8764. Alpha's checks include the electrode and lead, the gas valve and pressure, the flue and its terminal, the combustion settings and the burner earth.

Check they're on the Gas Safe Register before work starts.

If your boiler is still under guarantee, contact Alpha first: Alpha technical helpline 0344 871 8764.

Typical repair costs

What you pay depends on the cause. If it's the gas supply or a frozen condensate pipe there may be no repair at all; a new ignition or flame sensing electrode costs far less than a new gas valve or control board. Ask for the diagnosis before any parts are fitted.

UK guide prices for this fault
JobTypical price
Gas valve replacement, labour and materials£180 to £220

Source: Checkatrade, updated October 2026. Guide prices, not quotes.

For call-out, hourly and emergency rates, see typical boiler repair costs.

Which Alpha boilers show E38

BoilerWhat you'll see
Alpha E-Tec 28 and 33E38, usually seen in the fault history (INFO menu d9).

The same fault on other brands

A flame that goes out while the boiler is running shows up under a different code on each make of boiler:

See every code in this group on the ignition and flame faults page.

Sources

We take every code meaning from Alpha's own documents. Read how we check our codes.

  1. E-Tec 28 and 33 installation and servicing instructions (Alpha Heating Innovation, January 2022), section 10.2, pages 47 to 49.

Codes last checked against the manufacturers' manuals on 25 November 2026.