E61 on an Alpha boiler means air in the pump, or a restriction in the heating circuit, is restricting the flow. Alpha's checks are that the flow and return valves are open, the system pressure is correct and the system has been purged of air.
Safe checks firstSimple checks outside the boiler casing often clear this code. If it keeps coming back, call a Gas Safe registered engineer.
What E61 means
Alpha's description: Restricted CH flow due to air or a circuit restriction.
Alpha describes E61 as air in the pump: restricted central heating flow due to air or a circuit restriction. Its checks are that the flow and return valves are open, the system pressure is correct and the system has been properly purged.
Common causes
- Air in the system, often after it's been drained or refilled.
- Closed flow or return valves.
- Low pressure.
What you can safely try
Only if you feel confident, and only outside the casing:
- Check the valves under the boiler and on radiators are open.
- Bleed the radiators. See how to bleed a radiator.
- Top up the pressure if it has dropped. See how to repressurise a boiler.
- Reset the boiler.
What not to try
- Don't open the casing or keep resetting the boiler: work inside a gas boiler is a job for a Gas Safe registered engineer.
When you need a Gas Safe engineer
If E61 returns, call a Gas Safe registered engineer or Alpha's technical helpline on 0344 871 8764 to purge the system properly.
Check they're on the Gas Safe Register before work starts.
If your boiler is still under guarantee, contact Alpha first: Alpha technical helpline 0344 871 8764.
Typical repair costs
Topping up the pressure yourself costs nothing. If it keeps dropping, the price depends on what the engineer finds: a leaking radiator valve is a small job, while a new pump, pressure relief valve or expansion vessel costs more.
For call-out, hourly and emergency rates, see typical boiler repair costs.
Which Alpha boilers show E61
| Boiler | What you'll see |
|---|---|
| Alpha E-Tec 28 and 33 | E61. |
Other Alpha codes
The same fault on other brands
A pump or circulation fault shows up under a different code on each make of boiler:
- A1 281Worcester BoschPump stuck or running drySafe checks first
- F.83VaillantNo temperature rise when the burner startsEngineer needed
- FAIdealFlow and return reversedSafe checks first
- E125BaxiCirculation faultEngineer needed
- F.83Glow-wormNo temperature rise when the burner startsEngineer needed
- 89ViessmannPump blockedEngineer needed
See every code in this group on the water pressure and circulation faults page.
Sources
We take every code meaning from Alpha's own documents. Read how we check our codes.
- E-Tec 28 and 33 installation and servicing instructions (Alpha Heating Innovation, January 2022), section 10.2, pages 47 to 49.
Codes last checked against the manufacturers' manuals on 25 November 2026.