E47 on an Alpha boiler means the flue gases reached 110 °C, so the boiler has reduced its output to prevent damage. If the temperature keeps rising, it locks out with E03. Alpha lists poor water flow and flue restrictions as causes. Get it checked.
Engineer neededYou can make the safe checks below once. If the code comes back, the fault is inside the boiler and needs a Gas Safe registered engineer.
What E47 means
Alpha's description: Flue thermostat has sensed high flue gas temperature (110 °C) and reduced the burner output.
Alpha describes E47 as reduced burner output: the flue thermostat sensed a high flue gas temperature of 110 °C and turned the burner down to prevent damage. If the temperature keeps rising, the boiler locks out and shows E03.
Common causes
- Air in the heat exchanger.
- Restricted primary flow.
- Air flow through the heat exchanger blocked.
- A flue restriction or flue sensor fault.
What you can safely try
Only if you feel confident, and only outside the casing:
- Check the pressure.
- Bleed radiators with cold spots. See how to bleed a radiator.
What not to try
- Don't open the casing or keep resetting the boiler: work inside a gas boiler is a job for a Gas Safe registered engineer.
When you need a Gas Safe engineer
Book a Gas Safe registered engineer or call Alpha's technical helpline on 0344 871 8764. A hot flue means heat isn't going into the water as it should.
Check they're on the Gas Safe Register before work starts.
If your boiler is still under guarantee, contact Alpha first: Alpha technical helpline 0344 871 8764.
Typical repair costs
If low pressure or air caused the overheat, topping up or bleeding radiators may be all it needs. A sludged-up system, a failing pump or a faulty sensor costs more to put right.
For call-out, hourly and emergency rates, see typical boiler repair costs.
Which Alpha boilers show E47
| Boiler | What you'll see |
|---|---|
| Alpha E-Tec 28 and 33 | E47. |
Other Alpha codes
The same fault on other brands
An overheated flue shows up under a different code on each make of boiler:
See every code in this group on the overheating faults page.
Sources
We take every code meaning from Alpha's own documents. Read how we check our codes.
- E-Tec 28 and 33 installation and servicing instructions (Alpha Heating Innovation, January 2022), section 10.2, pages 47 to 49.
Codes last checked against the manufacturers' manuals on 25 November 2026.