Alpha E03 fault code explained

Engineer needed

E03 on an Alpha boiler means the flue temperature got too high and the flue sensor stopped the boiler. Alpha's manual lists restricted water flow, a blocked heat exchanger, a flue restriction or a faulty flue sensor. This needs a Gas Safe engineer.

Engineer neededYou can make the safe checks below once. If the code comes back, the fault is inside the boiler and needs a Gas Safe registered engineer.

What E03 means

Alpha's description: Flue sensor intervention (flue temperature too high).

Alpha describes E03 as high flue temperature, with the flue sensor intervening. Before E03, the boiler may first cut its output: Alpha's E47 means the flue reached 110 °C and output was reduced, and if the temperature keeps rising the boiler locks out with E03.

Common causes

  • Blocked or restricted primary water flow.
  • Air flow through the heat exchanger blocked.
  • A flue restriction.
  • A faulty flue sensor.

What you can safely try

Only if you feel confident, and only outside the casing:

  1. Check the pressure.
  2. Reset once. If E03 returns, leave the boiler off.

What not to try

  • Don't open the casing or keep resetting the boiler: work inside a gas boiler is a job for a Gas Safe registered engineer.

When you need a Gas Safe engineer

Call a Gas Safe registered engineer or Alpha's technical helpline on 0344 871 8764. If your carbon monoxide alarm sounds, switch off and call 0800 111 999.

Check they're on the Gas Safe Register before work starts.

If your boiler is still under guarantee, contact Alpha first: Alpha technical helpline 0344 871 8764.

Typical repair costs

If low pressure or air caused the overheat, topping up or bleeding radiators may be all it needs. A sludged-up system, a failing pump or a faulty sensor costs more to put right.

For call-out, hourly and emergency rates, see typical boiler repair costs.

Which Alpha boilers show E03

BoilerWhat you'll see
Alpha E-Tec 28 and 33E03.

The same fault on other brands

An overheated flue shows up under a different code on each make of boiler:

See every code in this group on the overheating faults page.

Sources

We take every code meaning from Alpha's own documents. Read how we check our codes.

  1. E-Tec 28 and 33 installation and servicing instructions (Alpha Heating Innovation, January 2022), section 10.2, pages 47 to 49.

Codes last checked against the manufacturers' manuals on 25 November 2026.