E45 on an Alpha boiler means the temperature difference between the water going out and coming back jumped unexpectedly. The boiler limits its output to protect itself and carries on once the difference is right again. Check the pressure and that valves are open.
Safe checks firstSimple checks outside the boiler casing often clear this code. If it keeps coming back, call a Gas Safe registered engineer.
What E45 means
Alpha's description: Sudden, unexpected increase in temperature difference between the flow sensor and the system return sensor.
Alpha describes E45 as high ΔT (temperature difference): the boiler has detected a sudden, unexpected increase in the difference between the flow sensor and the system return sensor.
Alpha says the burner's output is limited to protect the boiler, and normal operation resumes once the right difference is restored. The installer should make sure water is circulating, the pump is set up for the system and the return sensor is correct.
Common causes
- Poor circulation, for example closed valves or air.
- A pump not set up for the system.
- A return sensor problem.
What you can safely try
Only if you feel confident, and only outside the casing:
- Check the pressure. See what your boiler pressure should be.
- Open radiator valves.
- Bleed radiators with cold spots. See how to bleed a radiator.
What not to try
- Don't open the casing or keep resetting the boiler: work inside a gas boiler is a job for a Gas Safe registered engineer.
When you need a Gas Safe engineer
If E45 keeps appearing, call a Gas Safe registered engineer or Alpha's technical helpline on 0344 871 8764 to check the circulation and the pump settings.
Check they're on the Gas Safe Register before work starts.
If your boiler is still under guarantee, contact Alpha first: Alpha technical helpline 0344 871 8764.
Typical repair costs
If low pressure or air caused the overheat, topping up or bleeding radiators may be all it needs. A sludged-up system, a failing pump or a faulty sensor costs more to put right.
For call-out, hourly and emergency rates, see typical boiler repair costs.
Which Alpha boilers show E45
| Boiler | What you'll see |
|---|---|
| Alpha E-Tec 28 and 33 | E45. |
Other Alpha codes
The same fault on other brands
Water temperature rising too fast shows up under a different code on each make of boiler:
See every code in this group on the overheating faults page.
Sources
We take every code meaning from Alpha's own documents. Read how we check our codes.
- E-Tec 28 and 33 installation and servicing instructions (Alpha Heating Innovation, January 2022), section 10.2, pages 47 to 49.
Codes last checked against the manufacturers' manuals on 25 November 2026.