Ignition and flame faults
An ignition or flame fault means the boiler tried to light its burner and couldn't detect a flame, or the flame went out while it was running. The boiler shuts the gas off and locks out to keep you safe.
These are the most common lockouts in winter. Very often the cause is outside the boiler: the gas supply is off, a prepayment meter has run out of credit, or the condensate pipe has frozen and backed up.
What you can usually check
- Check other gas appliances, such as the hob, are working. If none are, the problem is the gas supply, not the boiler. See checking your gas supply.
- If you have a prepayment meter, check it has credit.
- In freezing weather, check the plastic condensate pipe outside. See how to thaw a frozen condensate pipe.
- Then reset the boiler once. If the code comes back, call a Gas Safe registered engineer.
Ignition and flame faults by brand
| Brand | Code | What it means | What to do |
|---|---|---|---|
| Worcester Bosch | EA 227 | No flame detected after ignition | Safe checks first |
| Worcester Bosch | EA 229 | Flame lost while the boiler was running | Safe checks first |
| Worcester Bosch | F7 228 | Flame signal before the burner started | Engineer needed |
| Worcester Bosch | FA 306 | Flame signal after the gas valve closed | Engineer needed |
| Vaillant | F.28 | Boiler failed to light | Safe checks first |
| Vaillant | F.29 | Flame went out and the boiler couldn't relight | Safe checks first |
| Vaillant | F.27 | Flame detected while the burner is off | Engineer needed |
| Vaillant | F.53 | Combustion control fault | Safe checks first |
| Vaillant | F.54 | Gas supply fault | Safe checks first |
| Vaillant | F.57 | Not burning correctly in comfort mode | Safe checks first |
| Vaillant | F.62 | Delay in the flame going out | Engineer needed |
| Ideal | L2 | Ignition lockout | Safe checks first |
| Ideal | F2 | Flame loss | Safe checks first |
| Baxi | E133 | Gas supply or ignition failure | Safe checks first |
| Baxi | E128 | Flame failure during operation | Safe checks first |
| Baxi | E.04.10 | Burner failed to ignite | Safe checks first |
| Baxi | E.04.12 | Ignition failure: flame monitoring | Engineer needed |
| Baxi | E.01.04 | Flame lost five times in 24 hours | Safe checks first |
| Glow-worm | F.28 | Boiler failed to light | Safe checks first |
| Glow-worm | F.29 | Flame went out and didn't relight | Safe checks first |
| Glow-worm | F.27 | Flame detected while the burner is off | Engineer needed |
| Viessmann | 67 | Flame signal out of range | Safe checks first |
| Viessmann | 346 | Flame signal calibration error | Safe checks first |
| Viessmann | 68 | Flame detected before the burner started | Engineer needed |
| Alpha | E01 | Ignition failure | Safe checks first |
| Alpha | E20 | Flame sensing fault | Engineer needed |
| Alpha | E38 | Flame lost (can be high winds) | Safe checks first |
| Alpha | E43 | Repeated flame loss | Engineer needed |